XX002 Rev 799 Surveyor99 Dome System
Technical Information
••••
55
Technical Information
ELECTRICAL
Drive Type:
Electrical motorized pan and tilt, electronic control.
Camera Types:
Units available in monochrome (EIA/CCIR) and color (NTSC/
PAL).
Input Voltage:
20 - 34 VAC.
Wire Size for Specified Cable Run Lengths:
See Table 6.
Wire Size (AWG) (Annealed
Copper Wire)
Distance: Indoor Unit, ft (m)
Distance: Outdoor Unit, ft (m)
24 VAC
28 VAC
24 VAC
28 VAC
20
115 (35)
285 (85)
53 (17)
140 (44)
18
180 (55)
445 (135)
87 (27)
220 (67)
16
285 (90)
710 (215)
134 (40)
360 (113)
14
460 (140)
1135 (345)
213 (67)
567 (173)
12
720 (220)
1770 (540)
333 (100)
887 (273)
Table 6
Applicable Wire Size
Current:
Indoor: 1.2 A nominal.
Outdoor: 2.0 A (heater included).
Power Consumption:
Indoor: 28.8 W nominal.
Outdoor: 48.0 W nominal (heater included).
Heat Equivalent:
Indoor: 1.6 btu/min (0.4 cal/min).
Outdoor: 2.7 btu/min (0.6 cal/min).
Note: These figures represent the conversion of 100% of the electrical energy to heat. Actual percentage of
the heat generated will be less and will vary from product to product. These figures are provided as an
aid in determining the extent of cooling required for an installation.
Program Memory Type:
Field re-programmable flash type memory.
Connectors Types:
Video:
BNC-F.
Power:
Removable screw Terminal Block (TB1), 3 position.
Control Input/Output:
Removable screw Terminal Block (TB3), 5 position or RJ-45
(J3) connector.
Relay Output:
RJ-45 (J3) connector.
Alarm Input:
RJ-45 (J2) connector.
Video Output Impedance:
75 ohms.
Содержание Surveyor 99
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ......
Страница 38: ...28 Installation XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 48: ...38 Wiring XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 52: ...42 Configuration XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 54: ...44 Disassembling the Surveyor99 XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 58: ...48 Operation XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 60: ...50 Maintenance XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 62: ...52 Shipping Instructions XX002 Rev 799 Surveyor99 Dome System NOTES...