Technical Information
XX002 Rev 799 Surveyor99 Dome System
ENVIRONMENTAL
Operating Temperature Range:
Indoor: 35 to 140°F (2 to 60°C).
Outdoor: -40 to 140°F (-40 to 60°C).
Operating Humidity Range:
Indoor: up to 90% relative, noncondensing.
Outdoor: 100% relative.
Storage Temperature Range:
-40
°
to 150
°
F (-40
°
to 65
°
C).
Storage Humidity Range:
Up to 90% relative, noncondensing.
Wind Load:
Outdoor: heavy rain or snow driven by winds up to 80 mph.
MODEL NUMBER PRODUCT
CODE
ENVIRONMENT
CAMERA TYPE
MOUNT
TYPE
ZOOM
OUTER DOME
TYPE
SURV99-MC-1
6483-00
Indoor
Monochrome/EIA
Ceiling
16x
Color
SURV99-MC-1C
6483-01
Indoor
Monochrome/CCIR
Ceiling
16x
Color
SURV99-CC-2
6725-04
Indoor
Color/NTSC
Ceiling
22x
Color
SURV99-CC-1C
6484-01
Indoor
Color/PAL
Ceiling
16x
Color
SURV99-MP-1
6485-00
Indoor
Monochrome/EIA
Pendant
16x
Color
SURV99-MP-1C
6485-01
Indoor
Monochrome/CCIR Pendant
16x
Color
SURV99-PC-2
6721-04
Indoor
Color/NTSC
Pendant
22x
Color
SURV99-CP-1C
6486-01
Indoor
Color/PAL
Pendant
16x
Color
SURV99-MW-1
6487-00
Outdoor
Monochrome/EIA
Pendant
16x
Clear
SURV99-MW-1C
6487-01
Outdoor
Monochrome/CCIR Pendant
16x
Clear
SURV99-WC-2
6723-04
Outdoor
Color/NTSC
Pendant
22x
Clear
SURV99-CW-1C
6488-01
Outdoor
Color/PAL
Pendant
16x
Clear
Table 7
Model Descriptions
MOUNTING TYPE
TOTAL diameter
(in/cm)
OUTER DOME
diameter
(in/cm)
TOTAL height
(in/cm)
In-Ceiling
7.1 (18.0)
5.9 (15.0)
8.8 (22.3)
Indoor Pendant
8.0 (20.3)
5.9 (15.0)
9.2 (23.4)
Outdoor Pendant
9.0 (22.8)
5.9 (15.0)
9.3 (23.6)
Table 8
Dimensions
Содержание Surveyor 99
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ......
Страница 38: ...28 Installation XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 48: ...38 Wiring XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 52: ...42 Configuration XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 54: ...44 Disassembling the Surveyor99 XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 58: ...48 Operation XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 60: ...50 Maintenance XX002 Rev 799 Surveyor99 Dome System NOTES...
Страница 62: ...52 Shipping Instructions XX002 Rev 799 Surveyor99 Dome System NOTES...