4.6 Dial Pulse Signaling
Description
An analog CO Line can be configured to send dial pulse signals to the central office. If
programmed as a pulse CO line, the system will send open loop pulses at 10 pps with the
assigned break/make ratio.
Operation
System
Operation of this feature is automatic when programmed.
Conditions
1. The break/make ratio is system programmable as 60/40 or 66/33.
2. You can change the signaling from pulse to DTMF by dialing ‘*’ while on a Line
assigned for pulse signaling.
Programming
Keyset Admin.
CO/IP
CO Line Signal Type (PGM 141-Button 5)
SYSTEM
Pulse Dial (Break/Make) Ratio (PGM 176)
Pause Timer (PGM 181-Button 10)
Web Admin.
CO LINE DATA
Common Attributes
Analog Attributes
CO Line Signal
SYSTEM DATA
Pulse Dial (Break/Make) Ratio
System Timers
Pause Timer
Related Features