Summit & Summit 800
Feature Description and Operation Manual
Issue 1.2
233
2.78
System Alarm Notification Control
Description
The system has several fault alarms that can be enabled or disabled. When enabled, a Station
within each Zone can be assigned to receive a notification of the alarm event. Alarms that can be
enabled are:
Emergency call placed
Digital (BRI or E1/PRI) Line fault
SIP Trunk/Extension registration fault.
Assigned stations receive the fault Alarm Signal, either a single tone burst repeated at 1-minute
intervals or a continuous tone. The Alarm Signal may be terminated at the phone by dialing the
Alarm Stop code or, if assigned, pressing the
{ALARM STOP}
button. To rearm the Alarm
function, the alarm condition must be cleared and the Alarm signal terminated.
When enabled, the Emergency call or fault event causes an alarm ring at the Station. The
Station can terminate the fault Alarm notification
Operation
System
At detection of fault or Emergency Call, the Alarm signal is sent to assigned stations.
iPECS IP & LDP Phones
To assign a Flex button as an {ALARM STOP} button to terminate the Alarm Signal:
[TRANS/PGM]
+
{FLEX}
+ “565” +
[HOLD/SAVE]
To terminate an Alarm Signal, while idle:
1. Dial the Flex Numbering Plan code “565”, confirmation tone is received and the Alarm
Signal is terminated. If the alarm condition is cleared, the system will automatically rearm
the alarm monitoring.
Or,
Press the
{ALARM STOP}
button.
Conditions
1. The station must terminate the Alarm signal at their phone. However, a Main
Attendant can terminate the Alarm signal at the System Attendant.
2. When no station is assigned to receive an Alarm, the System Attendant will receive the
notification.
3. For Digital Line and SIP registration faults, the station in the Zone associated with first
Line of the BRI/E1/PRI interface or SIP channel receives the alarm signal.
4. The notification process for Emergency calls follows the Zone from which the call was
made and the System Attendant. The notified station can review the history of
Emergency calls only from the Zone. The System Attendant can review Emergency