External Connections
VL-486-4 Reference Manual
Installation – 51
J2 – D
IGITAL
I/O C
ONNECTOR
Table 27: Digital I/O Connector Pinout
J2
Pin
Signal
Name
Function
1
PA0
Port A Data 0
2
Ground
Ground
3
PA1
Port A Data 1
4
Ground
Ground
5
PA2
Port A Data 2
6
Ground
Ground
7
PA3
Port A Data 3
8
Ground
Ground
9
PA4
Port A Data 4
10
Ground
Ground
11
PA5
Port A Data 5
12
Ground
Ground
13
PA6
Port A Data 6
14
Ground
Ground
15
PA7
Port A Data 7
16
Ground
Ground
17
PB0
Port B Data 0, Counter/Timer 2 Output
18
Ground
Ground
19
PB1
Port B Data 1, Counter/Timer 2 Count Input
20
Ground
Ground
21
PB2
Port B Data 2, Counter/Timer 2 Trigger Input
22
Ground
Ground
23
PB3
Port B Data 3, Counter/Timer 2 Gate Input
24
Ground
Ground
25
PB4
Port B Data 4, Counter/Timer 1 Output
26
Ground
Ground
27
PB5
Port B Data 5, Counter/Timer 1 Count Input
28
Ground
Ground
29
PB6
Port B Data 6, Counter/Timer 1 Trigger Input
30
Ground
Ground
31
PB7
Port B Data 7, Counter/Timer 1 Gate Input
32
Ground
Ground
33
Power
+5V Rack Power
34
Ground
Ground
PA0-PA7 — Port A Data Lines.
These TTL input/output signals transfer information
between the CIO Port A and external devices. The signals can be configured as inputs, outputs,
tri-state, or open-drain.
PB0-PB7 — Port B Data Lines.
These TTL input/output signals transfer information
between the CIO Port B and external devices. They may also be used to provide external access
to CIO Counter/Timers 1 and 2. The signals can be configured as inputs, outputs, tri-state, or
open-drain.
Power — +5V Power Output.
When jumper V1 is installed, up to 500 mA can be drawn
from this +5V output to power the Opto 22 interface rack or other external equipment. If the I/O
rack is powered by a separate external supply, the power jumper on the I/O rack or the V1
jumper must be removed. This output is fused with a resettable polyfuse rated at 1A.