Functional Description
CG Drives & Automation, 01-5326-01r3b
Load Settings from Control Panel [245]
This function can load all four parameter sets from the
control panel to the AC drive. Parameter sets from the
source AC drive are copied to all parameter sets in the target
AC drive, i.e. A to A, B to B, C to C and D to D.
Start commands will be ignored during loading.
Communication information
11.2.7 Trip Autoreset/Trip Conditions
[250]
The benefit of this feature is that occasional trips that do not
affect the process will be automatically reset. Only when the
failure keeps on coming back, recurring at defined times and
therefore cannot be solved by the AC drive, will the unit give
an alarm to inform the operator that attention is required.
For all trip functions that can be activated by the user you
can select to control the motor down to zero speed according
to set deceleration ramp to avoid water hammer.
Also see section 12.2, page 198.
Autoreset example:
In an application it is known that the main supply voltage
sometimes disappears for a very short time, a so-called “dip”.
That will cause the AC drive to trip an “Undervoltage
alarm”. Using the Autoreset function, this trip will be
acknowledged automatically.
•
Enable the Autoreset function by making the reset input
continuously high.
•
Activate the Autoreset function in the menu [251],
Number of trips.
•
Select in menus [252] to [25N] the Trip condition that
are allowed to be automatically reset by the Autoreset
function after the set delay time has expired.
Number of Trips [251]
Any number set above 0 activates the Autoreset. This means
that after a trip, the AC drive will restart automatically
according to the number of attempts selected. No restart
attempts will take place unless all conditions are normal.
If the Autoreset counter (not visible) contains more trips
than the selected number of attempts, the Autoreset cycle
will be interrupted. No Autoreset will then take place.
If there are no trips for more than 10 minutes, the Autoreset
counter decreases by one.
If the maximum number of trips has been reached, the trip
message hour counter is marked with an “A”.
If the Autoreset is full then the AC drive must be reset by a
normal Reset.
Example:
•
Number of allowed autoreset attempts [251]= 5.
•
Within 10 minutes 6 trips occur.
•
At the 6th trip there is no autoreset, because the
autoreset counter is set to allow only 5 attempts to
autoreset a trip.
•
To reset the autoreset counter, give a new reset command
(from one of the sources for reset control selected in
menu [216]).
•
The autoreset counter is now zeroed.
Default:
No Copy
No Copy
0
Nothing will be loaded.
A
1
Data from parameter set A is loaded.
B
2
Data from parameter set B is loaded.
C
3
Data from parameter set C is loaded.
D
4
Data from parameter set D is loaded.
ABCD
5
Data from parameter sets A, B, C and D are
loaded.
A+Mot
6
Parameter set A and Motor data are
loaded.
B+Mot
7
Parameter set B and Motor data are
loaded.
C+Mot
8
Parameter set C and Motor data are
loaded.
D+Mot
9
Parameter set D and Motor data are
loaded.
ABCD+Mot 10
Parameter sets A, B, C, D and Motor data
are loaded.
M1
11 Data from motor 1 is loaded.
M2
12 Data from motor 2 is loaded.
M3
13 Data from motor 3 is loaded.
M4
14 Data from motor 4 is loaded.
M1M2M3
M4
15 Data from motor 1, 2, 3 and 4 are loaded.
All
16
All data is loaded from the control panel.
Modbus Instance no/DeviceNet no:
43025
Profibus slot/index
168/184
EtherCAT index (hex)
4bd1
Profinet IO index
19409
Fieldbus format
UInt
Modbus format
UInt
NOTE: Loading from the control panel will not affect the
value in menu [310].
245 Load from CP
Stp
No Copy
9(0R'ULYH 96, 9(0 U
Содержание VEMoDRIVE VSI 2.0 HD
Страница 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Страница 2: ......
Страница 4: ......
Страница 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 206: ...204 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 243: ...241 9 0R ULYH 96 9 0 U...