Functional Description
CG Drives & Automation, 01-5326-01r3b
Motor Current [224]
Set the nominal motor current. If parallel motors, set the
value as sum of motors current.
Communication information
Motor Speed [225]
Set the nominal asynchronous motor speed.
Communication information
Motor Poles [226]
When the nominal speed of the motor is
≤
500 rpm, the
additional menu for entering the number of poles, [226],
appears automatically. In this menu the actual pole number
can be set which will increase the control accuracy of the AC
drive.
Communication information
Motor Cos
ϕ
[227]
Set the nominal Motor cosphi (power factor).
Communication information
Default:
I
MOT
(see Note 2 page 80)
Range:
25 - 150% x I
NOM
Modbus Instance no/DeviceNet no:
43044
Profibus slot/index
168/203
EtherCAT index (hex)
4be4
Profinet IO index
19428
Fieldbus format
Long, 1=0.1 A
Modbus format
EInt
NOTE: The default settings are for a standard 4-pole
motor according to the nominal power of the AC drive.
WARNING!
Do not connect motors with less than 25% of
the nominal power of the AC drive. This may
disrupt the control of the motor.
Default:
n
MOT
(see Note 2 page 80)
Range:
30 - 18000 rpm
Resolution
1 rpm, 4 sign digits
WARNING!
Do NOT enter a synchronous (no-load) motor
speed.
NOTE: Maximum speed [343] is not automatically
changed when the motor speed is changed.
NOTE: Entering a wrong, too low value can cause a
dangerous situation for the driven application due to
high speeds.
224 Motor Curr
Stp
M1:
(IMOT)A
225 Motor Speed
Stp
M1:
(
n
MOT
)
rpm
Modbus Instance no/DeviceNet no:
43045
Profibus slot/index
168/204
EtherCAT index (hex)
4be5
Profinet IO index
19429
Fieldbus format
UInt. 1=1 rpm
Modbus format
UInt
Default:
4
Range:
2-144
Modbus Instance no/DeviceNet no:
43046
Profibus slot/index
168/205
EtherCAT index (hex)
4be6
Profinet IO index
19430
Fieldbus format
Long, 1=1 pole
Modbus format
EInt
Default:
Cos
Ƶ
NOM
(see Note 2 page 80)
Range:
0.45 - 1.00
Modbus Instance no/DeviceNet no:
43047
Profibus slot/index
168/206
EtherCAT index (hex)
4be7
Profinet IO index
19431
Fieldbus format
Long, 1=0.01
Modbus format
EInt
226 Motor Poles
Stp
M1:
4
227 Motor Cos
ϕ
Stp
M1:Cos
ij
NOM
9(0R'ULYH 96, 9(0 U
Содержание VEMoDRIVE VSI 2.0 HD
Страница 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Страница 2: ......
Страница 4: ......
Страница 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 206: ...204 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 243: ...241 9 0R ULYH 96 9 0 U...