11.6.6 Counters [660]
Counter functions for counting pulses and signalling on
digital output when counter reaches specified high and low
limit levels.
The counter is counting up on positive flanks on the
triggered signal, the counter is cleared as long as the Reset
signal is active.
The counter can be automatically decremented with
specified decrement time, if no new trigger signal has
occurred within the decrement time.
The counter value is clamped to the high limit value and the
digital output function (C1Q or C2Q) is active when
counter value equals high limit value.
See Fig. 124 for more information of the counters.
Fig. 124 Counters, operating principle.
Counter 1 [661]
Counter 1 parameter group.
Counter 1 Trigger [6611]
Selection of the digital output signal used as trigger signal
for counter 1. Counter 1 is incremented by 1 on every
positive flank on the trigger signal.
Communication information
Counter 1 Reset [6612]
Selection of the digital signal used as reset signal for counter
1. Counter 1 is cleared to 0 and held to 0 as long as reset
input is active (high).
Communication information
Counter 1 High value [6613]
Sets counter 1 high limit value. Counter 1 value is clamped
to selected high limit value and the counter 1 output (C1Q)
is active (high) when the counter value equals the high value.
Communication information
NOTE: Maximum counting frequency is 8 Hz.
Default:
Off
Selection:
Same selections as “Digital Out 1 [541]”.
6619
6615
6614
6611
6612
541
541 = Digital Out 1 function
6611= Counter 1 trigger
6612= Counter 1 reset
6613= Counter 1 High value
6614= Counter 1 Low value
6615= Counter 1 Decrement timer
6619= Counter 1 value
6613
6611 C1 Trig
Stp
Off
Modbus Instance no/DeviceNet no:
43571
Profibus slot/index
170/220
EtherCAT index (hex)
4df3
Profinet IO index
19955
Fieldbus format
UInt
Modbus format
UInt
NOTE: Reset input has top priority.
Default:
Off
Selection:
Same selections as “Digital Out 1 [541]”.
Modbus Instance no/DeviceNet no:
43572
Profibus slot/index
170/221
EtherCAT index (hex)
4df4
Profinet IO index
19956
Fieldbus format
UInt
Modbus format
UInt
NOTE: Value 0 means that counter output is always
true (high).
Default:
0
Range:
0 - 10000
Modbus Instance no/DeviceNet no:
43573
Profibus slot/index
170/222
EtherCAT index (hex)
4df5
Profinet IO index
19957
Fieldbus format
Long, 1=1
Modbus format
EInt
6612 C1 Reset
Stp
Off
6613 C1 High Val
Stp
0
9(0R'ULYH 96, 9(0 U
Содержание VEMoDRIVE VSI 2.0 HD
Страница 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Страница 2: ......
Страница 4: ......
Страница 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 206: ...204 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 243: ...241 9 0R ULYH 96 9 0 U...