CG Drives & Automation, 01-5326-01r3b
191
11.7.3 Stored values [730]
The shown values are the actual values built up over time.
Values are stored at power down and updated again at power
up.
Run Time [731]
Displays the total time that the AC drive has been in the
Run Mode.
Communication information
Reset Run Time [7311]
Reset the run time counter. The stored information will be
erased and a new registration period will start.
Communication information
Mains time [732]
Displays the total time that the AC drive has been connected
to the mains supply. This timer cannot be reset.
Communication information
Energy [733]
Displays the total energy consumption since the last energy
reset [7331] took place.
Communication information
Unit:
h: mm:ss (hours: minutes: seconds)
Range:
00: 00: 00–262143: 59: 59
Modbus Instance no/DeviceNet no:
31028:31029:31030
(hr:min:sec)
Profibus slot/index
121/172:121/173: 121/
174
EtherCAT index (hex)
2404:2405:2406
Profinet IO index
1028:1029:1030
Fieldbus format
Long, 1=1h:m:s
Modbus format
Eint
Default:
No
No
0
Yes
1
Modbus Instance no/DeviceNet no:
7
Profibus slot/index
0/6
EtherCAT index (hex)
2007
Profinet IO index
7
Fieldbus format
UInt
Modbus format
UInt
NOTE: After reset the setting automatically reverts to
“No”.
731 Run Time
Stp
h:mm:ss
7311 Reset RunTm
Stp
No
Unit:
h: mm:ss (hours: minutes: seconds)
Range:
00: 00: 00–262143: 59: 59
Modbus Instance no/DeviceNet no:
31031:31032:31033
(hr:min:sec)
Profibus slot/index
121/175:121/176: 121/
177
EtherCAT index (hex)
2407 : 2408 :
2409
Profinet IO index
1031:1032:1033
Fieldbus format
Long, 1=1h:m:s
Modbus format
Eint
Unit:
Wh (shows Wh, kWh, MWh or GWh)
Range:
0.0–1GWh,
Counter will restart at 0 after 1GWh
Modbus Instance no/DeviceNet no:
31034
Profibus slot/index
121/178
EtherCAT index (hex)
240a
Profinet IO index
1034
Fieldbus format
Long, 1=1 Wh
Modbus format
EInt
732 Mains Time
Stp
h:mm:ss
733 Energy
Stp
kWh
9(0R'ULYH 96, 9(0 U
Содержание VEMoDRIVE VSI 2.0 HD
Страница 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Страница 2: ......
Страница 4: ......
Страница 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 206: ...204 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 243: ...241 9 0R ULYH 96 9 0 U...