CG Drives & Automation, 01-5326-01r3b
193
Trip message [811]-[81P]
The information from the status menus are copied to the
trip message log when a trip occurs.
Communication information
Example:
Fig. 131 shows the third trip memory menu [830]: Over
temperature trip occurred after 1396 hours and 13 minutes
in Run time.
Fig. 131 Trip 3
11.8.2 Trip Messages [820] - [890]
Same information as for menu [810].
Communication information
All nine alarm lists contain the same type of data. For
example DeviceNet parameter 31101 in alarm list 1
contains the same data information as 31151 in alarm list 2.
Trip menu Copied from
Description
811
711
Process Value
812
712
Speed
813
712
Torque
814
714
Shaft Power
815
715
Electrical Power
816
716
Current
817
717
Output voltage
818
718
Frequency
819
719
DC Link voltage
81A
71A
Heatsink Temperature
81B
71B
PT100_1, 2, 3
81C
721
AC drive Status
81D
723
Digital input status
81E
724
Digital output status
81F
725
Analogue input status 1-2
81G
726
Analogue input status 3-4
81H
727
Analogue output status 1-2
81I
728
I/O status option board 1
81J
729
I/O status option board 2
81K
72A
I/O status option board 3
81L
731
Run Time
81M
732
Mains Time
81N
733
Energy
81O
310
Process reference
81P
72C
VIO Status
Modbus Instance no/DeviceNet no:
31102 - 31135
Profibus slot/index
121/246 - 254,
122/0 - 24
EtherCAT index (hex)
244e - 246f
Profinet IO index
1102 - 1135
Fieldbus format
Depends on parameter, see
respective parameter.
Modbus format
Depends on parameter, see
respective parameter.
Modbus Instance no/
DeviceNet no:
31151–31185
31201–31235
31251–31285
31301–31335
31351–31385
31401–31435
31451–31485
31501–31535
Trip log list
2
3
4
5
6
7
8
9
Profibus slot/index
122/40–122/74
122/90–122/124
122/140–122/174
122/190–122/224
122/240–123/18
123/35 - 123/68
123/85–123/118
123/135–123/168
Trip log list
2
3
4
5
6
7
8
9
EtherCAT index (hex)
247e - 24b0
24b1 - 24e2
24e3 - 2514
2515 - 2546
2547 - 2578
2579 - 25aa
25ab - 25dc
25dd - 260e
Trip log list
2
3
4
5
6
7
8
9
Profinet IO index
1151 - 1185
1201 - 1235
1251 - 1285
1301 - 1335
1351 - 1385
1401 - 1435
1451 - 1485
1501 - 1535
Trip log list
2
3
4
5
6
7
8
9
Fieldbus format
See Trip 811 - 81O
Modbus format
830 Over temp
Stp
1396h:13m
9(0R'ULYH 96, 9(0 U
Содержание VEMoDRIVE VSI 2.0 HD
Страница 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Страница 2: ......
Страница 4: ......
Страница 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 206: ...204 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Страница 243: ...241 9 0R ULYH 96 9 0 U...