Introduction
LFXG-H Installation and Operation Guide
17
LFXG-H specifications
Table 1.1
LFXG-H specifications
System
Accuracy
±1% of span
typical
Accuracy depends on specific application
parameters
Active Lengths
Flexible detector
305 – 7,010 mm (12 – 276") in 305 mm
(12") increments
Typical
Sources
Cesium-137
0.66 MeV gamma radiation emitter, 30.2
year half life
Cobalt-60
1.2 and 1.3 MeV gamma radiation emitter,
5.3 year half life
Power
Requirements*
AC
100 – 230 ±10% VAC (90 – 250 VAC, or
with internal heater kit: 115 – 230 VAC) at
50/60 Hz, at 15 VA maximum power
consumption (25 VA
with heater) CE
compliance requires 100 – 230
±10% VAC
DC
20 – 60 VDC (< 100 mV, 1/1,000 Hz ripple)
at 15 VA
CE compliance requires 24 VDC ± 10%
Wiring
Per local code
Signal Cable
Maximum length
1,000 m (3,280
'
)
HART signal
1.02 – 0.643 mm (no. 18 or 20 AWG) 2-
conductor shielded