141
© VeEX Inc. All Rights Reserved.
Ethernet
l
Sync Header Error
l
Block Type Error
l
FCS/CRC:
Number of received frames with an invalid Frame Check Sequence (FCS)
l
IP Checksum:
Invalid IP Frame Check sequence
l
TCP/UDP Checksum
(Layer 4 only)
l
Jabber frames:
Number of received frames larger than 1518 bytes containing an invalid FCS
l
Runt frames:
Number of received frames smaller than 64 bytes containing an invalid FCS
l
Giant frames
(Advanced Monitoring - Pass Through Results only):
Number of received frames lar-
ger than 1518 bytes
Throughput Results - Global Errors
The
Global Alarms
screen displays the Current and Total alarm count of all streams:
l
LOS:
Loss of Signal
l
LOSync:
Loss synchronization
l
Service disruption associated with loss of signal:
l
Current:
Duration of the current service disruption
l
Total:
Total accumulated duration of the service disruptions
Содержание MTX150 Series
Страница 1: ...MTX150x User Manual Multi Service Installation Maintenance Test Set P N D07 00 148P Rev B00 ...
Страница 11: ...Customer Care 303 Table of Contents VeEX Inc All Rights Reserved 11 ...
Страница 171: ...171 VeEX Inc All Rights Reserved Ethernet V FTP Setup Download V FTP Download Results SyncE ...
Страница 246: ...Common Functions VeEX Inc All Rights Reserved 246 Bluetooth Devices Bluetooth Scan ...
Страница 248: ...Common Functions VeEX Inc All Rights Reserved 248 Bluetooth Devices Bluetooth Scan ...
Страница 267: ...267 VeEX Inc All Rights Reserved Common Functions ...
Страница 300: ...Software Update Pro cess VeEX Inc All Rights Reserved 300 Software Version is displayed in the About section ...