Fiber Channel
© VeEX Inc. All Rights Reserved.
224
l
Constant:
Continuous traffic (no traffic shaping)
l
Burst:
Two burst bandwidths are configured with variable burst time in seconds
l
Ramp:
Start and stop bandwidths are configured along with the bandwidth step size and dur-
ation
l
Frame Size:
Set the frame size in bytes.
l
Available in FC-2 mode only
l
Valid settings are 56 bytes to 2148 bytes.
l
The frame length includes the SOF and EOF overhead bytes.
l
Constant Bandwidth:
Configure the transmit rate or bandwidth in %
l
Valid settings are 1% to 100% in 0.01% increments
FC-BERT/FC-Throughput Traffic Setup
Error Injection Setup
Error injection can be performed during a test. The type of errors and error injection rate or flow are configured
in the Error Injection tab.
l
Error type:
Select from Bit and CRC.
l
Injection Flow:
Determines how the selected errors will be injected. The user can select a single
error injection, a specific count, or error rate.
l
Count:
When Count is selected, configure the error count via the numeric pop-up keypad.
Содержание MTX150 Series
Страница 1: ...MTX150x User Manual Multi Service Installation Maintenance Test Set P N D07 00 148P Rev B00 ...
Страница 11: ...Customer Care 303 Table of Contents VeEX Inc All Rights Reserved 11 ...
Страница 171: ...171 VeEX Inc All Rights Reserved Ethernet V FTP Setup Download V FTP Download Results SyncE ...
Страница 246: ...Common Functions VeEX Inc All Rights Reserved 246 Bluetooth Devices Bluetooth Scan ...
Страница 248: ...Common Functions VeEX Inc All Rights Reserved 248 Bluetooth Devices Bluetooth Scan ...
Страница 267: ...267 VeEX Inc All Rights Reserved Common Functions ...
Страница 300: ...Software Update Pro cess VeEX Inc All Rights Reserved 300 Software Version is displayed in the About section ...