as the distance between nodes or link partners increases, so does the time it takes for the transmitting node to
receive the R_RDY frame because of signal propagation delay. The standard practice for a 1Gbps Fibre Chan-
nel link is to allow 1 buffer credit for each 2km of distance.
Setup
FC-1 BERT - Test Frame Setup
l
Profile:
User Defined Profile or Default setting can be used for testing.
l
Test layer:
FC-1 or FC-2 only. Testing at other layers is not supported.
l
FC-1:
Information is transmitted using an adaptive code (8B/10B or 64/66B) depending on test rate
and the encoding process results in the generation of transmission characters.
l
The two types of Transmission Characters defined are data and special. Certain com-
binations of Transmission Characters, referred to as Ordered Sets, are designated by
this standard to have special meaning.
l
Ordered Sets are used to identify frame boundaries, transmit primitive function
requests, and maintain proper link transmission characteristics during periods of inactiv-
ity.
Содержание MTX150 Series
Страница 1: ...MTX150x User Manual Multi Service Installation Maintenance Test Set P N D07 00 148P Rev B00 ...
Страница 11: ...Customer Care 303 Table of Contents VeEX Inc All Rights Reserved 11 ...
Страница 171: ...171 VeEX Inc All Rights Reserved Ethernet V FTP Setup Download V FTP Download Results SyncE ...
Страница 246: ...Common Functions VeEX Inc All Rights Reserved 246 Bluetooth Devices Bluetooth Scan ...
Страница 248: ...Common Functions VeEX Inc All Rights Reserved 248 Bluetooth Devices Bluetooth Scan ...
Страница 267: ...267 VeEX Inc All Rights Reserved Common Functions ...
Страница 300: ...Software Update Pro cess VeEX Inc All Rights Reserved 300 Software Version is displayed in the About section ...