![background image](http://html.mh-extra.com/html/vbrick/9000-series/9000-series_admin-manual_857502091.webp)
Encoder Configuration
VBrick 9000 Encoder Admin Guide
83
Enable Automatic
Latency Control
Default = Disabled. This option offers an easy way to adjust the gap
settings to minimize the latency for particular content and
configuration parameters. The latency control values are set based on
certain configuration parameters. For more information about this
topic see Automatic Latency Control .
Note: The default gap and latency settings for Transport Stream have
not been optimized. If you have a requirement for low overhead or
low latency, you will need to manually tune these settings for optimal
performance.
Enable FEC
Enable Forward Error Correction. For a detailed description of FEC
parameters see Enable Forward Error Correction (FEC) on a Stream.
Field
Description