5-22
Valco Cincinnati, Inc.
Section 5 - Operation
MC091 - VCX OT-120 FlexosealPro 2 - Corrugated
Jam Detection Menu Dialog -
Continued
Name
Use
Machine Speed
The current speed of the machine.
Products per Hour
The current number of products per hour.
Apply Button
Applies the Jam Dimension Length to all scanners that are on.
Alarm On/Off
Turn the alarm on or off.
Auto Stop Machine
On/Off
Auto stop stops the machine when a jam is detected. This
switch turns the auto stop feature on and off.
Fault Description
Summary Bar
Displays the most recent fault(s).
Date and Time
The current date and time.
Jam Detection:
Relay
This value determines how many seconds the machine stop
signal will remain active after an active scanner detects a jam
and the machine is stopped. NOTE: This feature will only work
if the Auto Stop Machine On/Off Switch is “On.”
Jam Detection:
Speed Threshold
Setting
The active scanners will not scan for jams until the machine is
running at or above this speed. The speed is measured in
meters per minute or feet per minute.
Scanner On/Off
Switch
Use to turn the scanners on and off.
Note: The assigned scanner must be on for Jam Detection to
function properly.
Dimension Length/
Individual Scanner
Length Settings
Set an individual detection length for each active scanner.
When the scanner detects any product longer than this length,
it will signal a jam.
Repeat Dimension
Length
Use to set the Dimension Length for all scanners that are on
(must press the Apply Button for this to take effect)