6-41
Valco Cincinnati, Inc.
Section 6 - Customize the Settings
MC091 - VCX OT-120 FlexosealPro 2 - Corrugated
Tipsealer Air Cylinder Timing Values - Continued
Figure 6-71. Tipsealer Air Cylinder Timing Values
Valve movement from
Tipsealer Pad (park)
to Gluing Position
T1
T2
Valve movement from
Gluing Position to
Tipsealer Pad (park)
T3
T4
TipSealer Air Cylinder Timing Values
Name
Comment
Default
Min
Max
Tipsealer Enable
0 = Disabled, 1 = Enabled
0
0
1
TipSealer T1
TipSealer Time 1 in [ms]
500
100
2000
TipSealer T2
TipSealer Time 2 in [ms]
500
100
2000
TipSealer T3
TipSealer Time 3 in [ms]
500
100
2000
TipSealer T4
TipSealer Time 4 in [ms]
500
100
2000
TipSealer Feed Timeout
Timeout after Feedstop in [sec]
15
5
60
TipSealer Feed Polarity
Polarity of Feedstop Signal
0
0
1
TipSealer Pos.Switch Enable
Position Switch Enabled*
0
0
1
Pulse Purge Activation
Number of Pulses at beginning of
purge cycle
0 0
50
Tipsealer Output Manual
This output is active when the
control is in the MANUAL mode.
0 = No Output
1 = Glue Fault Light (Blue)
2 = Jam Fault Light (Red)
3 = Buzzer
4 = Low Level Light (Amber)
5 = Relay 1
6 = Relay 2
0 0
6
Tipsealer Output Error
This output is active when the
control is in the MANUAL mode.
0 = No Output
1 = Glue Fault Light (Blue)
2 = Jam Fault Light (Red)
3 = Buzzer
4 = Low Level Light (Amber)
5 = Relay 1
6 = Relay 2
0 0
6
Glue Station Type 1
Glue Station Type.
0 = Not Installed
1 = Boardrunner NC-3
2 = Boardrunner NC-4
3 = Boardrunner NC-Hybrid
4 = Boardrunner Contact Single
5 = Boardrunner Contact Dual
6 = BoardRunner FLP-3
7 = BoardRunner FLP-4
8 = Separated Valve NC
1 0
8
Tipsealer Jog On Restart
Cycle number when the valves will
switch to Jogg mode, after a restart.
0 0
25
* The Position Switch is an optional feature.