3-23
Valco Cincinnati, Inc.
Section 3 - Basic Features
MC091 - VCX OT-120 FlexosealPro 2 - Corrugated
Pattern Control Module (PCM),
Standard (074xx043) - Continued
Pattern Control Module Features
Status LEDs:
Number Name/Description
2
Supply Scanner/Logic (1 and 2)
CAN –S - Illuminates steady green when two-way
communication is occurring. Flashes green when the
communication channel is open but a signal is not being
received at the present time.
3
CAN –E - Illuminates green when there is an error with
communication.
4
Valve Power Supply LEDs (1-4)
5 Valve
Activation
LEDs
(1-4)
6
Trigger Status LEDs (1-4)
7
Scanner Status LEDs (1-4)
8
EPC Status LEDs (1-2)
9
Encoder Status LEDs (1-2)
Pattern Control Module Features
Connectors:
Number Name
1 Diagnostic
Port
10
Valve Connections (1-4)
11
Scanner Connections (1-4)
12
EPC 2 Connection
13
EPC 1 In/Out Connections
14
Scanner Junction Box (E-Box) Port
15
Valve Junction Box (E-Box) Port
Pattern Control Module Features
Fuses:
Number
Fuse
Type
Part No.
16a
Fuse Power Supply – Scanner, EPC, Purge (F1)
2A
085xx220
16b
Fuse Power Supply – Valve 1 (F2)
2A
085xx220
16c
Fuse Power Supply – Valve 2 (F3)
2A
085xx220
16d
Fuse Power Supply – Valve 3 (F4)
2A
085xx220
16e
Fuse Power Supply – Valve 4 (F5)
2A
085xx220