Section 5 - Operation
MC091 - VCX OT-120 FlexosealPro 2 - Corrugated
Configure the Inspection Sensor(s) - Continued
Name
Use
Trigger (Non-selectable)
Indicates if the inspection scanner is the internal scanner (INT)
or an assigned scanner.
Scan-Sensor Distance
The distance from the inspection sensor to the scanner being
used for inspection.
Minimum Speed Threshold
The minimum speed necessary for the inspection sensor to
inspect the glue lines
.
Correction Factor
Not Used.
Offset Start
Used to adjust the start of the glue line due to sensor width. (A
positive number forces an earlier start and a negative number
forces a later start.)
Offset End
Used to adjust the end of the glue line due to sensor width. (A
positive number forces a later end and a negative number
forces an earlier end.)
Min. Glue Length
The minimum length of glue the sensor will be allowed to
detect.
Min Gap Length
The minimum gap (without glue) the sensor will be allowed to
detect. Gaps smaller than this will appear as glue.
Threshold
Used to influence the inspection to look for glue at percentage
levels of the sensors output signal. A higher threshold
percentage is used to require a higher glue output signal for the
sensor to recognize glue. Often a higher percentage is used
when inspecting boxes that have printing.
Consecutive Faults Num/Enable
Number of consecutive faults that may occur before the system
shuts down.
Glue Fault Light Enable
Turns the Fault-Alert Light on or off.
Glue Fault Buzzer Enable
Turns the Fault-Alert Buzzer on or off.
Confirmation Button
Press to enter the new settings and go back to the Main Menu.
Cancel Button
Cancel the new settings and return to the previous settings.