12-2
Valco Cincinnati, Inc.
Section 12 - Diagnostic Menu
MC032 - MCP-25 Control
Diagnostic
Parameters
Scan
Scan
Scan
Scan
Scan
Scanners 1-4
L = Low (not active)
H = High (active)
This diagnostic menu for scanners is
used when testing the scanner signal
by placing your hand under the
scanner. When the parent machine is
operating, use the front-panel LEDs for
diagnostics.
Valve
Valve
Valve
Valve
Valve
L = The valve has not been selected for the current job.
H = The valve has been selected for the current job.
E = Error (The valve driver is defective or has been removed.)
- = The valve driver has not been installed.
Td1 and Td2
Td1 and Td2
Td1 and Td2
Td1 and Td2
Td1 and Td2
Pressure transducer (1-2) output pressure in percent.
Enc
Enc
Enc
Enc
Enc
The machine speed
Bp1 and Bp2
Bp1 and Bp2
Bp1 and Bp2
Bp1 and Bp2
Bp1 and Bp2
Bypass valves 1-2
L = Not active
H = Active
E = Error
- = The bypass valve has not been configured
Com 1 and Com 2
Com 1 and Com 2
Com 1 and Com 2
Com 1 and Com 2
Com 1 and Com 2
Computer interface 1 and 2
To obtain the version number of the CPU, follow this step:
1.
Press F2 (VERSION). The version number and revision dates of
all three CPUs display.
F2
CPU Version
Number