4.1.1
Monitoring values 2 (Control keypad: menu M1.23)
Code
Parameter
Unit
ID
Description
G1.20
Monitor 2
V1.20.1 Current
A
1113 Unfiltered motor current
V1.20.2
Torque
%
1125
Unfiltered motor torque
V1.20.3 DC
Voltage
V
44 Unfiltered DC link voltage
V1.20.4
43
Table 4-2. Monitoring values 2
4.1.2
Fieldbus monitoring values (Control keypad: menu M1.23)
Code
Parameter
Unit
ID
Description
G1.21
Fieldbus
V1.20.1
Motor Current 1D
A
45
Motor current (drive independ-
ent) given with one decimal
point
V1.24.5
Last Active Fault
37
Table 4-3. Fieldbus monitoring values
4.1.3 Application
Status
Word
Application Status Word combains different drive statuses to one data word.
See monitoring value V1.20.4 Status Word.
Application Status Word
FALSE
TRUE
b0 -
-
b1
Not in Ready state
Ready
b2 Not
Running
Running
b3 No
Fault
Fault
b4 -
-
b5 -
-
b6
Run Disabled
Run Enable
b7 No
Warning
Warning
b8
b9
b10
b11
No DC brake
DC Brake is active
b12
No Run Request
Run Request
b13
No Limit Controls Active
Limit control Active
b14 -
-
b15
Table 4-4. Application Status Word Content.