ASFIFF12 High Speed
vacon • 55
24-hour s358 (0)40 837 1150 • Email: [email protected]
1515
Low Speed Option HW
Hardware based Low Speed Option, 0 = enabled, 1 = disabled
The intention is to improve operation in low frequencies (<100Hz)
The parameter is only usable with Fr10 and bigger, and CH61 and bigger.
Both ID1514 and ID1515 have to be switched off when not in use.
1516
Advanced Options 2
By changing the value of this WORD -type variable is it possible to activate different bits
of the Advanced Options 2 variable.
Sel.
Advanced options 2
B0
Sensor less control = 1
B1
1 = Master controlled Id-control in sync. master/follower.
applications
0 = independent Id-control in master and followers
B2
Reserved
B3
Reserved
B4
PM motor; 1 = enable start-positioning
damping
B5
Enable
1517
Advanced Options 4
By changing the value of this WORD -type variable is it possible to activate different bits
of the Advanced Options 4 variable.
Sel.
Advanced options 4
B0
1 = activate roll-back prevention control
B1
1= do PMSM start angle ID only once after power up
B2
1 = enable sin/cos interpolation (for sin/cos encoder
testing)
B3
1 = enable dc-compensation (fast OL)
1518 Modulator
Type
Sel.
Advanced options 4
0
Default PWM
1
Space Vector PWM