8.- TECHNICAL SUPPORT
- 80 -
7.- TROUBLESHOOTING
SYMPTOM
PROBLEM
SOLUTION
The power switch (4) is turned on
but the power indicator (2) does not
light up.
Power cable not properly
connected or there is no
power supply.
Connect properly or
check the supply.
The fuse has blown.
Replace fuse (see
section 6.4). If the
problem persists, send
the equipment to an
authorized technical
service.
The equipment is faulty.
Send the equipment to
an authorized technical
service.
There is voltage in the cables but
none of the test voltage indicating
LED‟s (1) lights up.
One of the indicators has
blown.
Send the equipment to
an authorized technical
service.
The equipment is faulty.
Send the equipment to
an authorized technical
service.
One external equipment
sets his voltage on the
cables.
Review the
measurement‟s
conditions and that the
machine is fully
discharged.
The equipment generates voltage but
this is not present in the cables.
The high voltage cables are
not properly connected.
Connect properly
changing previously to
zero the voltage.
The high voltage cables are
in poor condition.
Contact an authorized
technical service.
The equipment is faulty.
Send the equipment to
an authorized technical
service.
Содержание UM2B
Страница 2: ......
Страница 49: ...5 SOFTWARE DESCRIPTION 47 Figure 5 18 Warning message Figure 5 19 a Measurement Screen Recovery Voltage ...
Страница 67: ...5 SOFTWARE DESCRIPTION 65 Figure 5 46 a First page of the report Recovery Voltage ...
Страница 68: ...5 SOFTWARE DESCRIPTION 66 Figure 5 47 a Second page of report Recovery Voltage ...
Страница 69: ...5 SOFTWARE DESCRIPTION 67 Figure 5 48 Third page of report Recovery Voltage ...
Страница 70: ...5 SOFTWARE DESCRIPTION 68 Figure 5 46 b First page of the report Insulation Resistance ...
Страница 71: ...5 SOFTWARE DESCRIPTION 69 Figure 5 47 b Second page of the report Insulation Resistance ...
Страница 87: ...8 TECHNICAL SUPPORT 85 Description of fault Materials returned on of of the year Table 8 1 ...