5.- SOFTWARE DESCRIPTION
- 48 -
Insulation Resistance Software (ETPRA)
In this screen is performed the measurement of insulation resistance. The upper part
of the measurement screen (Figure 5-19-b) includes a graphic that will show the evolution of
the insulation resistance throughout the test. The lower left-hand part of the screen shows
information on the insulation resistance at two moments in time (minutes 1 and 10), as well
as the polarization index and test voltage. To the right are two indicators: one indicates the
complete elapsed time (including the machine‟s discharge time) and the other the time it will
take to measure the insulation resistance. This last one will pause at the moment in which the
unit is performing the measurement. When arriving zero, the test will be over.
Figure 5-19-b: Measurement Screen (Insulation Resistance).
Содержание UM2B
Страница 2: ......
Страница 49: ...5 SOFTWARE DESCRIPTION 47 Figure 5 18 Warning message Figure 5 19 a Measurement Screen Recovery Voltage ...
Страница 67: ...5 SOFTWARE DESCRIPTION 65 Figure 5 46 a First page of the report Recovery Voltage ...
Страница 68: ...5 SOFTWARE DESCRIPTION 66 Figure 5 47 a Second page of report Recovery Voltage ...
Страница 69: ...5 SOFTWARE DESCRIPTION 67 Figure 5 48 Third page of report Recovery Voltage ...
Страница 70: ...5 SOFTWARE DESCRIPTION 68 Figure 5 46 b First page of the report Insulation Resistance ...
Страница 71: ...5 SOFTWARE DESCRIPTION 69 Figure 5 47 b Second page of the report Insulation Resistance ...
Страница 87: ...8 TECHNICAL SUPPORT 85 Description of fault Materials returned on of of the year Table 8 1 ...
Страница 95: ...APPENDIX B CONTROL SOFTWARE 93 APPENDIX A CE CONFORMITY DECLARATION ...