2.2
Control Panel
9
2
2.2
Control Panel
Fig.2-2
Outline View of Control Panel
(1) AC INPUT connector .......................Power cable receptacle.
(Refer to Section 5.2 "Connection of Power Cable".)
(2) POWER Switch................................Power switch.
(3) START/STOP button .......................Push to acceleration or deceleration.
During LOCAL MODE, control by maintained push.
(4) RESET button ..................................When occur ALARM or WARNING, after remedying the
cause of the ALARM, an abnormal state is released by
pushing button. By maintained push, REMOTE MODE
and LOCAL MODE are changed.
(5) POWER lamp...................................This lamp lights or blinks while power on. (green)
lights : REMOTE MODE
blinks : LOCAL MODE
(6) ROTATION lamp .............................Operation indicator lamp indicating that the pump's rotor
is running. (green)
(7) STATUS lamp .................................Operation indicator lamp indicating that the pump's
operation status. (green
・
orange) (Note 1)
green/lights : Rotational speed reaches 80 % rated value
green/blinks : Accelerating
orange/lights : ALARM occurs
orange/blinks : Warning occurs
(8) NET lamp .........................................This lamp is always turned off.
(Note 1) The pattern when both green and orange are lit and blink becomes the following.
・
When warning occurred during rating speed.
green/light and orange/blink : green - orange - green - orange - …
・
When warning occurred during acceleration.
green/blink and orange/blink : green - orange - turned off - green - orange - turned off -…
Содержание UTM3400 Series
Страница 2: ...This page is intentionally left blank...
Страница 10: ...viii Location of Label...
Страница 20: ...6 1 1 2 Descriptions This page is intentionally left blank...
Страница 21: ...2 2IDENTIFICATION AND FUNCTION 2 1 Pump Main Unit 2 2 Control Panel 2 3 External I F Panel...
Страница 25: ...3 3CONSTRUCTION AND PRINCIPLE 3 1 Pump Construction 3 2 Principle of Turbo Molecular Pumping 3 3 Controller...
Страница 30: ...16 3 3 3 Controller This page is intentionally left blank...
Страница 36: ...22 4 4 3 Standards Fulfilled This page is intentionally left blank...
Страница 50: ...36 5 5 5 Notes on Transportation This page is intentionally left blank...
Страница 72: ...58 6 6 8 Communication Specifications This page is intentionally left blank...
Страница 73: ...7 7GAS PURGE...
Страница 82: ...68 8 8 6 Turbo Molecular Pump Return Request This page is intentionally left blank...
Страница 95: ...10 10WARRANTY CLAUSES...
Страница 98: ...84 10 This page is intentionally left blank...
Страница 100: ...Index Index 2 This page is intentionally left blank...