5.4
Bank 3
Bank 3 contains interrupt parameters. Some interrupts need configuration (e.g. the timer interval of
a timer interrupt). This can be done using the SGP commands with parameter bank 3 (SGP <type>, 3,
<value>).
The priority of an interrupt depends on its number. Interrupts with a lower number have
a higher priority.
Table
shows all interrupt parameters that can be set. Please see table
for an explanation of the
parameter access types.
Interrupt Parameters in Bank 3
Number
Global Parameter
Description
Range [Units]
Access
0
Timer 0 period
(ms)
Time between two interrupts
0. . . 4294967295
[ms]
RW
1
Timer 1 period
(ms)
Time between two interrupts
0. . . 4294967295
[ms]
RW
2
Timer 2 period
(ms)
Time between two interrupts
0. . . 4294967295
[ms]
RW
27
Stop left 0 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both
0. . . 3
RW
28
Stop right 0 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both
0. . . 3
RW
39
Input 0 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both
0. . . 3
RW
40
Input 1 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both
0. . . 3
RW
41
Input 2 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both
0. . . 3
RW
42
Input 3 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both
0. . . 3
RW
43
Input 4 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both
0. . . 3
RW
44
Input 5 trigger
transition
0=off, 1=low-high, 2=high-low, 3=both
0. . . 3
RW
Table 20: Interrupt Parameters in Bank 3