TMCM-1211 TMCL
™
Firmware Manual • Firmware Version V1.10 | Document Revision V1.00 • 2018-OCT-02
107 / 133
Number
Axis Parameter
Description
Range [Units]
Access
204
Freewheeling
mode
Stand
still
option
when
the
standby
current
(parameter
7)
is
set
to
zero.
0
normal operation
1
freewheeling
2
coil shorted using low side drivers
3
coil shorted using high side drivers
0. . . 3
RW
206
Actual load
value
Readout of the actual load value used for stall
detection (stallGuard2).
0. . . 1023
R
207
Extended error
flags
A
combination
of
the
following
values:
1
stallGuard error
2
deviation error
These error flags are cleared automatically
when this parameter has been read out or when
a motion command has been executed.
0. . . 3
R
208
Motor driver
error flags
A
combination
of
the
following
values:
Bit 0
stallGuard2 status
(1: stall detected)
Bit 1
Overtemperature
(1: driver is shut down due to overtemper-
ature)
Bit 2
Overtemperature pre-warning
(1: temperature threshold is exceeded)
Bit 3
Short to ground A
(1: short condition detected, driver cur-
rently shut down)
Bit 4
Short to ground B
(1: short condition detected, driver cur-
rently shut down)
Bit 5
Open load A
(1: no chopper event has happened during
the last period with constant coil polarity)
Bit 6
Open load B
(1: no chopper event has happened during
the last period with constant coil polarity)
Bit 7
Stand still
(1: no step pulse occurred during the last
2
20
clock cycles)
0. . . 255
R
209
Encoder
position
Encoder counter value.
-2147483648
. . . 2147483647
[µsteps]
RW
210
Encoder
resolution
Encoder counts per round.
0. . . 65535
RW
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.