TMCM-1211 TMCL
™
Firmware Manual • Firmware Version V1.10 | Document Revision V1.00 • 2018-OCT-02
62 / 133
3.6.29
AAP (Accu to Axis Parameter)
The content of the accumulator register is transferred to the specified axis parameter. For practical usage,
the accumulator has to be loaded e.g. by a preceding GAP instruction. The accumulator may have been
modified by the CALC or CALCX (calculate) instruction.
This command is mainly intended for use in standalone
mode.
Info
For a table with parameters and values which can be used together with this
command please refer to section
Related commands:
AGP, SAP, GAP, SGP, GGP, GIO, GCO, CALC, CALCX.
Mnemonic:
AAP <parameter number>, <motor number>
Binary Representation
Instruction
Type
Motor/Bank
Value
34
see chapter
0
<value>
Reply in Direct Mode
Status
Value
100 - OK
don’t care
Example
Position motor #0 by a potentiometer connected to analog input #0:
1
Start :
GIO 0,1
// get value of analog input line 0
3
CALC MUL , 4
// multiply by 4
AAP 0,0
// transfer result to target position of motor 0
5
JA Start
// jump back to start
Binary Form of AAP 0, 0
Field
Value
Target address
01
h
Instruction number
22
h
Type
00
h
Motor/Bank
00
h
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
00
h
Value (Byte 0)
00
h
Checksum
23
h
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at