Number
Axis Parameter
Description
Range [Units]
Access
212
Maximum
encoder
deviation
When the actual position (parameter 1) and the
encoder position (parameter 209) differ more
than set here the motor will be stopped. This
function is switched off when the maximum de-
viation is set to zero.
0. . . 65535
[encoder
steps]
RW
214
Power down
delay
Standstill period before the current will be
ramped down to standby current. The standard
value is 200 (which means 2000ms).
0. . . 417
[10ms]
RW
251
Reverse shaft
Reverse the rotation direction of the motor
shaft.
0/1
RW
255
Unit mode
Units of velocity and acceleration/deceleration
settings:
0 - the internal units of the motion controller are
used directly
1 - the units are pps for velocity and pps
2
for
acceleration/deceleration
Default value is 1 (pps units).
0/1
RW
Table 16: All TMCM-1211 Axis Parameters