Firmware Manual • Firmware Version V1.10 | Document Revision V1.00 • 2018-OCT-02
42 / 133
Reply (Status=no error, Value=302)
Field
Value
Host address
02
h
Target address
01
h
Status
64
h
Instruction
0F
h
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
01
h
Value (Byte 0)
2E
h
Checksum
A5
h
Bank 0 – Digital Inputs
The analog input lines can be read as digital or analog inputs at the same time. The digital input states can
be accessed in bank 0.
Digital Inputs in Bank 0
Port
Command
Range
AIN0
GIO 0, 0
0/1
PWMD0
GIO 1, 0
0/1
PWMD1
GIO 2, 0
0/1
PWMD2
GIO 3, 0
0/1
PWMU0
GIO 4, 0
0/1
PWMU1
GIO 5, 0
0/1
PWMU2
GIO 6, 0
0/1
Special case:
GIO 255, 0 reads all general purpose inputs simulataneously and puts the result into the lower
eight bits of the accumulator register.
Bank 1 – Analog Inputs
The analog input lines can be read back as digital or analog inputs at the same time. The analog values
can be accessed in bank 1.
Analog Inputs in Bank 1
Port
Command
Range
AIN0
GIO 0, 1
0. . . 65535