TMCM-1211 TMCL
™
Firmware Manual • Firmware Version V1.10 | Document Revision V1.00 • 2018-OCT-02
25 / 133
3.6.3
MST (Motor Stop)
The motor is instructed to stop with a soft stop.
Internal function:
The velocity mode is selected. Then, the target speed (axis parameter #0) is set to zero.
Related commands:
ROR, ROL, SAP, GAP.
Mnemonic:
MST
<
axis
>
Binary Representation
Instruction
Type
Motor/Bank
Value
3
0
0
0
Reply in Direct Mode
Status
Value
100 - OK
don’t care
Example
Stop motor 0.
Mnemonic:
MST 0.
Binary Form of MST 0
Field
Value
Target address
01
h
Instruction number
03
h
Type
00
h
Motor/Bank
00
h
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
00
h
Value (Byte 0)
00
h
Checksum
04
h
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.