Superintend IMD
© Copyright Muuntosähkö Oy - Trafox
67
PEC-01 UNIT
Operating voltage 220…240VAC 48…62Hz
Input power 2W (35mA / 230VAC), internal fuse 80mAT PTC
Operating temperature: 0…50ºC, relative humidity: < 90%, non-condensing
Resistance measurement range: 0…2.55Ω, accuracy ±0.2Ω
RS-485 speed 9600bps
Connector tightening torque: 0.45…0.5 Nm
Weight: 0.47 kg
EMC standards: EN61326-2-4, EN55011, EN61000-3-2, EN61000-4-2, EN61000-
4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 (Tested on the
system level)
Other standards: IEC61557-8, IEC61010-1:2010-3
TC-01 and IC-01 UNITS
Operating voltage: 6-15VDC, max. 30mA @ 6V, typical 8mA @ 12V
Operating temperature 0…70ºC, relative humidity: < 90%, non-condensing
RS-485 speed 9600 bps
Connector tightening torque: 0.45…0.5 Nm
Weight: 86 g
EMC standards: EN61326-2-4, EN55011, EN61000-4-2, EN61000-4-3, EN61000-
4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 (Tested on the system level)
Other standards: IEC61557-8
RD-01 UNIT
Operating voltage: 6-15VDC, max. 71mA @ 6V, typical 35mA @ 12V
Operating temperature 0…70ºC, relative humidity: < 90%, non-condensing
RS-485 speed 9600 bps
Connector tightening torque: 0.45…0.5 Nm
Weight: 89 g
EMC standards: EN61326-2-4, EN55011, EN61000-4-2, EN61000-4-3, EN61000-
4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
Other standards: IEC61557-8
Содержание SUPERINTEND IC-01
Страница 8: ...8 Copyright Muuntosähkö Oy Trafox Superintend IMD http www trafox fi Figure 1 System connection ...
Страница 21: ...Superintend IMD Copyright Muuntosähkö Oy Trafox 21 http www trafox fi ...
Страница 23: ...Superintend IMD Copyright Muuntosähkö Oy Trafox 23 http www trafox fi ...
Страница 28: ...28 Copyright Muuntosähkö Oy Trafox Superintend IMD http www trafox fi ...
Страница 35: ...Superintend IMD Copyright Muuntosähkö Oy Trafox 35 http www trafox fi ...
Страница 37: ...Superintend IMD Copyright Muuntosähkö Oy Trafox 37 http www trafox fi ...
Страница 70: ...70 Copyright Muuntosähkö Oy Trafox Superintend IMD http www trafox fi 36 3 mm 110 mm 62 mm ...