A01607
H
A01608
SST
P23709
Tank
Lock
Plate
O--Ring
--
COOLING
RADIATOR
CO--17
(b)
Check the lock plate height (H) after completing the caulk-
ing.
Plate height (H):
7.4 -- 7.8 mm (0.2959 -- 0.3119 in.)
If not within the specified height, adjust the stopper bolt of the
handle again and caulk again.
6. PAINT LOCK PLATES
7 . I NS TALL DRAI N P LUG
(a)
Install a new O--ring to the drain plug.
(b)
Apply soapy water to the O--ring.
(c)
Install the drain plug.
8 . I NS TALL RADI ATO R S UP P O RTS
Install the 4 bolt and 2 radiator supports
Torque:13 N
∙
m (130 kgf
∙
cm, 9.6 ft
∙
lbf)
9 . CHE CK FO R WAT E R LE AKS
(a)
Using SST, plug the inlet and outlet pipes of the
radiator.
SST 09230 -- 01010
(b)
Using a radiator cap tester, apply pressure to the
radiator.
Test pressure:
147 kPa (1.5 kgf/cm
2
, 21 psi)
(c)
Check for water leaks.
HINT:
On radiators with resin tanks, there is a clearance between the
core plate and tank plate where a minute amount of air will re-
main, giving the appearance of an air leak when the radiator is
submerged in water. Therefore, before performing the water
leak test, first swirl the radiator around in the water until all air
bubbles disappear.