C-5
4)
Setting the frequency by voltage signals (0 to 10 Vdc)
+
:
Voltage signals 0-10Vdc
−
[Parameter setting]
Speed setting mode selection parameter
at
.
This setting cannot be made when the terminal II is
used.
5)
Setting the frequency by voltage signals (0 to +/-10Vdc)
The direction can be changed by switching between positive and negative signals.
+
:
Voltage signal 0-
±
10Vdc
−
[Parameter setting]
Speed setting mode selection parameter
at
.
Note)Set reference priority selection
at
(
, Default setting). Changing the
settings of two speed command parameters at a time, refer to 6.6.
[
Ex.: To set the frequency by current signal (4 to 20 mAdc) through the terminal]
Key operated
LED display
Operation
The running frequency is displayed. (Make this setting when the
motor is out of operation.) (If the monitor display mode setting
parameter
is set at
[Running frequency])
Press the [MON] key to call up the first basic parameter
(automatic acceleration/deceleration).
Select
by pressing the
△
or
▽
key.
Press the Enter key to display the parameter setting (set value).
(Default setting:
)
Change the parameter setting to
by pressing the
▽
key.
⇔
Press the Enter key to save the change. Then,
and the
set value are displayed alternately.
RX
CC
★
Voltage signal
Voltage signals (0 to +/-10 V) for setting the
operation frequency Refer to 7.3 for details
of adjustment.
-10Vdc
+10Vdc
Forward run
80Hz
80Hz
Reverse run
VI
CC
Frequency
80Hz
0
0Vdc
10Vdc
★
Voltage signal
Voltage signals (0 to 10 V) for setting the
operation frequency Refer to 7.3 for details of
adjustment.
MON
▲ ▼
ENT
▲ ▼
ENT
*
Necessary to change the VI/II input point 1 setting
.