I-8
No.
Option name
Function, purpose.
⑭
RS-232C
communication
converter cable
If this unit is used to connect the inverter and a personal computer and so on with each other, data communication can
be performed between the two besides easy adjustment of parameters, saving and writing data.
<Outline drawings with dimensions>
(Model: RS20035)
⑮
RS-485 communication
converter unit
(for communication with
multiple inverters)
More than one inverter can be controlled with a personal computer and so on if this unit is
used for connection between inverters and personal computer.
・
Computer link: Since this unit makes it possible to connect inverters with higher-class
computer, FA computer, etc., a data communication network can be
constructed among multiple inverters.
・
Communication among inverters: For the purpose of proportional operation of multiple
inverters, a frequency data communication network can
be constructed among multiple inverters.
<Outline drawings with dimensions>
(Model: RS4001Z) (Model: RS4002Z)
⑯
Communication cable
Connection cable for connecting parameter writer, extension control panel,
RS-232C communication units, and RS-485 communication units.
Cable types: CAB0011 (1 m), CAB0013 (3 m), CAB0015 (5 m).
⑰
Remote control panel
A frequency meter, frequency setup device, RUN/STOP (forward, reverse) switch
are built in this operation panel. (Model: CBVR-7B)
Applied control units of the AP series make various applied control possible if they
are used in combination with the inverter.
⑱
Application control units
■
Proportional control panel (APP-2B)
■
Ratio setup panel (APH-7B)
■
Regulated power supply board (APV-2B)
■
Cushion starter panel (APC-2B)
■
Synchronizing control panel
(APS-2B1)
■
Synchronizing transmitter (DRR-2)
■
Remote control panel (APM-2B)
■
Process control panel with built-in PI
controller (APJ-2B)
■
TG follower panel (APF-7B)
■
Current detection panel (APD-2B)
■
Torque control panel (APL-2B)
■
FV converter (APR-2B)
■
Loop controller (APU-2B)
⑲
Harmonic suppression
converter
Power regeneration
converter
・
Higher harmonic suppressor unit improves input power-factor by suppressing
harmonic current.
・
Power regenerator unit protects the inverter from load sprung from frequent rapid
deceleration and negative torque.
For applicable models and particulars, inquire at our office.
Option
⑩〜⑮
should be used under the condition of 9600 bps or less (
).
16
0
100
R2.5
18
0
16
8(
Mount
in
g
di
m
e
ns
io
n
)
6
25
16.5
8.5
R2.5
4
1
30
5
RJ45 connector
D-Sub 9pin connector
5m