F-64
Ex1:
=
(VI input),
=
(disabled)
Output frequency = Ref Over-ride (VI input [Hz])
Ex2:
=
(VI input),
=
(disabled)
Output frequency = Ref Over-ride(VI input [Hz])
2) Multiplicative over-ride
In this mode, each output frequency is multiplied by an externally override frequency.
[Ex1: RR(reference), VI(over-ride frequency)]
[Ex2: RX(reference), VI(over-ride frequency)]
Ex1:
=
(Disabled),
=
(VI input),
=
(RR input),
=
,
=
RR input(
=
,
=
,
=
,
=
)
VI input(
=
,
=
,
=
,
=
)
Note) Setting of RR input: Refer to 7.3.1, Setting of VI input: Refer to 7.3.2
Output frequency = Reference
×
{1 + Over-ride(VI input [%] / 100)}
Ex2:
=
(Disabled),
=
(VI input),
=
(RX input),
=
,
=
RX input(
=
,
=
,
=
,
=
)
VI input(
=
,
=
,
=
,
=
)
Note) Setting of RX input: Refer to 7.3.1, Setting of VI input: Refer to 7.3.2
Output frequency = Reference
×
{1 + Over-ride(VI input [%] / 100)}
Ex3:
Title
Function
Adjustment range
Default setting
Panel over-ride multiplication
gain
〜
[%]
Output frequency = Reference
×
{1 + Over-ride(
[%] / 100)}
Output frequency[Hz]
0
RR input
(reference)
10V
Over-ridden frequency
Output frequency [Hz]
0
RR input
(reference)
10V
Over-ridden frequency
(
)
(
)
Reverse