J-
9
[14] Tripless intensification setup (2/2)
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0307
Base frequency voltage
(Voltage compensation)
0: without voltage compensation (limitless output voltage)
1: with voltage compensation (limitless output voltage)
2: without voltage compensation (limited output voltage)
3: with voltage compensation (limited output voltage)
−
1
Disabled
This parameter is changeable,
but significant setting value is
fixed to 1 in vector control.
●
6.13.6
0308
Dynamic braking resistance
1.0
〜
1000 [
Ω
]
0.1/0.1
See J-28 Disabled
●
/
●
●
/
●
−
/
●
●
6.13.4
0309
Dynamic braking resistor capacity 0.01
〜
600.0 [kW]
0.01/0.01 See J-28 Disabled
●
/
●
●
/
●
−
/
●
●
6.13.4
0310
Ride-through time / Deceleration time 0.0
〜
320.0 [s]
0.1/0.01
2.0
Enabled
●
/
●
−
/
−
−
/
−
●
6.13.2
0311
Reverse-run prohibition
0: Permitted, 1: Reverse run prohibited,2: Forward run prohibited,
3: Direction designated by command permitted
−
0
Disabled
●
/
●
●
/
●
−
●
6.13.7
0312
Auto-restart adjustment #1
0.50
〜
2.50
0.01/0.01 See J-28 Enabled
●
/
●
●
/
●
−
/
−
●
6.13.1
0313
Auto-restart adjustment #2
0.50
〜
2.50
0.01/0.01 See J-28 Enabled
●
/
●
−
/
−
−
/
−
●
6.13.1
0314
Auto-restart mode
0
〜
4
1/1
See J-28 Disabled
●
/
−
●
/
−
−
/
−
●
6.13.1
0315
Auto-restart adjustment #3
0
〜
9
1/1
1
Disabled
●
/
−
●
/
−
−
/
−
●
6.13.1
[15] Drooping control
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0320
Drooping gain
0
〜
100 [%] (Enabled if
= 7, 8 or 9)
1/0.01
0
Enabled
●
/
●
−
−
−
6.14
0321
Speed at drooping gain 0%
0.0
〜
320.0 [Hz] (Enabled if
= 7, 8 or 9)
0.01/0.01
60.0
Enabled
●
/
●
−
−
−
6.14
0322
Speed at drooping gain
0.0
〜
320.0 [Hz] (Enabled if
= 7, 8 or 9)
0.01/0.01
60.0
Enabled
●
/
●
−
−
−
6.14
0323
Drooping insensitive torque band 0
〜
100 [%] (Enabled if
= 7, 8 or 9)
1/0.1
10
Enabled
●
/
●
−
−
−
6.14
0324
Output filter for drooping
0.1
〜
200.0 [rad/s] (Enabled if
= 7, 8 or 9)
0.1/0.1
100.0
Enabled
●
/
●
−
−
−
6.14
0325
Load inertia (Acc/Dec torque) 0
〜
1000
0.1/0.1
1.0
Enabled
●
/
●
−
−
−
※
0326
Load torque filter (Acc/Dec torque) 0.0
〜
199.9, 200.0:without filter
0.1/0.1
200.0
Enabled
●
/
●
−
−
−
※
0327
Drooping reference selection
0: Standard, 1: Acc/dec torque removal
2: Internal torque standard
3: Acc/dec torque removal (internal torque standard)
−
0
Enabled
●
/
●
−
−
−
※
[16] Functions for lift (1/2)
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0330
Light-load high-speed operation
0
〜
5
−
0
Disabled
●
/
●
−
−
●
※
0331
Light-load high-speed operation switching lower limit frequency 30.0
〜
[Hz]
0.01/0.01
40.0
Enabled
●
/
●
−
−
●
※
0332
Light-load high-speed operation load waiting time
0.0
〜
10.0 [s]
0.1/0.1
1.0
Enabled
●
/
●
−
−
●
※
0333
Light-load high-speed operation load detection time
0.0
〜
10.0 [s]
0.1/0.1
1.0
Enabled
●
/
●
−
−
●
※
0334
Light-load high-speed operation heavy load detection time 0.0
〜
10.0 [s]
0.1/0.1
5.0
Enabled
●
/
●
−
−
●
※
0335
Switching load torque current during forward run
0
〜
250 [%]
1
50
Enabled
●
/
●
−
−
●
※
0336
Heavy load torque during acceleration in forward direction
0
〜
250 [%]
1
150
Enabled
●
/
●
−
−
●
※
0337
Heavy load torque during fixed speed in forward direction
0
〜
250 [%]
1
100
Enabled
●
/
●
−
−
●
※
0338
Switching load torque current during reverse run
0
〜
250 [%]
1
50
Enabled
●
/
●
−
−
●
※
0339
Heavy load torque during acceleration in reverse direction
0
〜
250 [%]
1
150
Enabled
●
/
●
−
−
●
※
Sensorless vector/vector with sensor (
●
valid,
−
:invalid)
※
(Reference section): Refer to the inverter's individual manual.