J-
5
[5] Basic parameters #2
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0170
Base frequency #2
25.0
〜
400.0 [Hz]
0.01/0.01
60.0
Enabled
−
−
−
●
6.4.1
0171
Base frequency voltage #2
0.0
〜
600.0 [V]
0.1/0.1
See J-28 Enabled
−
−
−
●
6.4.1
0172
Manual torque boost #2
0.0
〜
30.0 [%]
0.1/0.01
See J-28 Enabled
−
−
−
●
6.4.1
0173
Motor overload protection level #2 10
〜
100 [%]
1/0.01
100.0
Enabled
−
−
−
●
6.4.1
0174
Base frequency #3
25.0
〜
400.0 [Hz]
0.01/0.01
60.0
Enabled
−
−
−
●
6.4.1
0175
Base frequency voltage #3
0.0
〜
600.0 [V]
0.1/0.1
See J-28 Enabled
−
−
−
●
6.4.1
0176
Manual torque boost #3
0.0
〜
30.0 [%]
0.1/0.01
See J-28 Enabled
−
−
−
●
6.4.1
0177
Motor overload protection level #3 10
〜
100 [%]
1/0.01
100
Enabled
−
−
−
●
6.4.1
0178
Base frequency #4
25.0
〜
400.0 [Hz]
0.01/0.01
60.0
Enabled
−
−
−
●
6.4.1
0179
Base frequency voltage #4
0.0
〜
600.0 [V]
0.1/0.1
See J-28 Enabled
−
−
−
●
6.4.1
0180
Manual torque boost #4
0.0
〜
30.0 [%]
0.1/0.01
See J-28 Enabled
−
−
−
●
6.4.1
0181
Motor overload protection level #4 10
〜
100 [%]
1/0.01
100
Enabled
−
−
−
●
6.4.1
0182
Motor switching mode selection
0: standard, 1: customized
-
0
Disabled
●
/
●
●
/
●
−
/
●
●
※
0183
V/f adjustment coefficient
0
〜
255
1/1
32
Enabled
−
−
−
●
※
[6] V/f 5-point setting
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0190
V/f 5-point setting VF1 frequency 0
〜
400 [Hz]
1/1
0
Disabled
−
−
−
●
6.5
0191
V/f 5-point setting VF1 voltage
0
〜
100 [%]
0.1/0.01
0.0
Disabled
−
−
−
●
6.5
0192
V/f 5-point setting VF2 frequency 0
〜
400 [Hz]
1/1
0
Disabled
−
−
−
●
6.5
0193
V/f 5-point setting VF2 voltage
0
〜
100 [%]
0.1/0.01
0.0
Disabled
−
−
−
●
6.5
0194
V/f 5-point setting VF3 frequency 0
〜
400 [Hz]
1/1
0
Disabled
−
−
−
●
6.5
0195
V/f 5-point setting VF3 voltage
0
〜
100 [%]
0.1/0.01
0.0
Disabled
−
−
−
●
6.5
0196
V/f 5-point setting VF4 frequency 0
〜
400 [Hz]
1/1
0
Disabled
−
−
−
●
6.5
0197
V/f 5-point setting VF4 voltage
0
〜
100 [%]
0.1/0.01
0.0
Disabled
−
−
−
●
6.5
0198
V/f 5-point setting VF5 frequency 0
〜
400 [Hz]
1/1
0
Disabled
−
−
−
●
6.5
0199
V/f 5-point setting VF5 voltage
0
〜
100 [%]
0.1/0.01
0.0
Disabled
−
−
−
●
6.5
※
(Reference section): Refer to the inverter's individual manual.