![Toshiba MMY-MAP0724HT6UL Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/toshiba/mmy-map0724ht6ul/mmy-map0724ht6ul_service-manual_1134809018.webp)
17
460 V / 3 Ph / 60 Hz
(Heat pump model)
TOSHIBA Carrier VRF Air conditioner
Outdoor unit set model name
MMY-
AP1444HT6UL AP1684HT6UL AP1924HT6UL AP2284HT6UL
Outdoor unit model name
MMY-MAP
0724HT6UL 0724HT6UL 0964HT6UL
0724HT6UL 0964HT6UL
0964HT6UL 1144HT6UL
1144HT6UL
Cooling Capacity
(*1) kBtu/h
144
168
192
220
Heating Capacity
(*1) kBtu/h
162
189
212
247
Power supply
(*2)
460 V 3 phase 60 Hz
Starting Current
A
Soft Start
Dimension
Unit
Height
In
72.8
72.8
72.8
72.8
72.8
72.8
72.8
72.8
Width
In
39.0
39.0
47.6
39.0
47.6
47.6
47.6
47.6
Depth
In
30.7
30.7
30.7
30.7
30.7
30.7
30.7
30.7
Packing
Height
In
76.3
76.3
76.3
76.3
76.3
76.3
76.3
76.3
Width
In
41.8
41.8
50.5
41.8
50.5
50.5
50.5
50.5
Depth
In
32.6
32.6
32.6
32.6
32.6
32.6
32.6
32.6
Total Weight Unit
lb
621
621
817
817
817
817
817
817
Packed unit
lb
654
654
855
855
855
855
855
855
Appearance (Color)
Silky shade (Munsell 1Y8.5/0.5)
Compressor
Type
Hermetic twin rotary compressor
Motor output
kW
2.3 x 2 2.3 x 2 2.1 x 3 2.3 x 2 2.1 x 3 2.1 x 3 2.5 x 3 2.5 x 3
Fan unit
Fan
Propeller fan
Motor output
W
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
Air volume
cfm
5,800
5,800
6,600
5,800
6,600
6,600
7,060
7,060
Heat exchanger
Finned tube
Refrigerant R410A(Charged refrigerant amount(lb))
(*3)
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
High-pressure switch
psi
OFF: 420 ON: 540
Protective devices
High-pressure switch / High-pressure sensor / Low-pressure sensor /
Fusible plug / PC board fuse / Inverter overload protector
Electrical
specifications Unit
MCA
(*4)
A
18
18
23
18
23
23
24
24
MOCP
(*5)
A
20
20
25
20
25
25
25
25
Refrigerant
piping
Connecting
port dia
Gas side (main pipe)
In
1-1/8"
1-1/8"
1-1/8"
1-3/8"
Liquid side (main pipe)
In
5/8"
5/8"
5/8"
3/4"
Balance pipe
In
3/8”
3/8”
3/8”
3/8”
System interconnection wiring
(Up to 3280 ft)
Shielded wire AWG16 x 2 cores
(Up to 6560 ft)
Shielded wire AWG14 x 2 cores
Operation temperature
range
Cooling
FDB
23 to 109
Heating
FWB
5 to 60
Max external static pressure
In WG
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
Max. No. of connected indoor units
24
28
32
38
Sound pressure level
Cooling/Heating
dB(A)
59/60
61.5/63.5
63/65
65/66
(*1) Rated conditions
Cooling : Indoor 80 degF Dry Bulb / 67 degF Wet Bulb, Outdoor 95 degF Dry Bulb.
Heating : Indoor 70 degF Dry Bulb, Outdoor 47 degF Dry Bulb / 43 degC WetBulb.
(*2) The source voltage must not fluctuate more than ±10 %
(*3) The amount dose not consider extra piping length. Refrigerant must be added on site in accordance with the actual
piping length.
(*4) Select wire size base on the larger value of MCA.
MCA : Minimum Circuit Amps (minimum circuit Amps required for power supply design.)
(*5) MOCP : Maximum Overcurrent Protection (Amps)
Содержание MMY-MAP0724HT6UL
Страница 229: ...228 15Exploded Diagram Parts Price List SMMS i OUTDOOR UNIT MMY MAP0724HT6UL ...
Страница 230: ...229 MMY MAP0724HT6UL ...
Страница 232: ...231 SMMS i OUTDOOR UNIT MMY MAP0964HT6UL MMY MAP1144HT6UL ...
Страница 233: ...232 MMY MAP0964HT6UL MMY MAP1144HT6UL ...
Страница 237: ...236 SMMS i INV SERVICE PARTS LIST MMY MAP0724HT6UL 4 pieces PC board ...
Страница 238: ...237 SMMS i INV SERVICE PARTS LIST MMY MAP0964HT6UL MMY MAP1144HT6UL 4 pieces PC board ...
Страница 241: ...Copyright 2011 TOSHIBA CARRIER CORPORATION ALL Rights Reserved ...