7 m
60
90
7 m
7 m
45
45
Remote control
•
A place where there are no obstacles such as a curtain that may block the signal from the remote control.
•
Do not install the remote control in a place exposed to direct sunlight or close to a heating source such as a stove.
•
Keep the remote control at least 1 m apart from the nearest TV set or stereo equipment (This is necessary to
prevent image disturbances or noise interference).
•
The location of the remote control should be determined as shown below.
Remote
control
Indoor unit
Reception range
(Side view)
(Top view)
* : Axial distance
Reception range
Remote control
4
4
INSTALLATION OF INDOOR UNIT
INSTALLATION OF INDOOR UNIT
WARNING
Install the air conditioner certainly to suffi ciently withstand the weight.
If the strength is insuffi cient, the unit may fall down resulting in human injury.
Perform a specifi ed installation work to guard against strong wind or earthquake.
An incomplete installation can cause accidents by the units falling and dropping.
REQUIREMENT
Strictly comply with the following rules to prevent damage of the indoor units and human injury.
• Do not put a heavy article on the indoor unit. (Even units are packaged)
• Carry in the indoor unit as it is packaged if possible. If carrying in the indoor unit unpacked by necessity, be sure to
use buffering cloth, etc. to not damage the unit.
• To move the indoor unit, do not apply force to the refrigerant pipe, drain pan, foamed parts, or resin parts, etc.
• Carry the package by two or more persons, and do not bundle it with plastic band at positions other than specifi ed.
Be careful to the following items when installing the unit.
• Considering air discharge direction, select an installation place where discharge air can circulate evenly in a room.
Avoid to install the unit at place with
“NO GOOD”
mark in the right fi gure.
OK
NO GOOD
: Not cooled well.
Bad installation place
Good installation place
Cooled well all over.
Screen
60
100
45
50
50
45
100
70
60
100
230
150
(700)
(600)
(205)
15
15
90
15
15
272
560
590
670
∅
5 mm hole
Clip anchor
(local parts)
Anchor bolt
Projection
15 mm or less
Cutting a hole
Mounting the installation plate and
screw position
1. After determining the pipe hole position, drill the pipe
hole (
∅
65 mm) at a slight downward slant to the
outdoor side.
Mounting screw
4 mm x 25
s
: Pipe hole (
∅
80 mm)
(Side piping)
(Rear piping)
(Bottom piping)
(Unit : mm)
Floor
Wall
5
5
CUTTING A HOLE AND MOUNTING INSTALLATION
CUTTING A HOLE AND MOUNTING INSTALLATION
PLATE
PLATE
CAUTION
When installing the installation plate with a mounting
screw, do not use the anchor bolt hole.
Otherwise the unit may fall down and result in personal
injury and property damage.
CAUTION
Failure to fi rmly install the unit may result in personal
injury and property damage if the unit falls.
• In case of block, brick, concrete or similar type walls,
make
∅
5 mm holes in the wall.
• Insert clip anchors for appropriate mounting screws.
OK
NO
GOOD
NO
GOOD
NOTE
• When drilling a wall that contains a metal lath, wire
lath or metal plate, be sure to use a pipe hole brim
ring sold separately.
NOTE
• Secure four corners and lower parts of the installation
plate with 6 mounting screws to install it.