GR
NL
PT
ES
IT
DE
FR
RU
SI
SK
LV
CS
TR
EN
L
N
50
10
20
70
Earth line
R (L)
S (N)
R (L) S (N)
,
,
,
Wiring connection
How to connect the power supply wiring and control wiring
REQUIREMENT
Connect the control wire after connecting the power supply wire for this model.
1) How to connect the power supply wiring
1. Removing the front panel.
2. Remove the terminal cover and cord clamp.
3. Take a power supply wire and control wire (according to the local rule) into the pipe hole on the hole.
4. Take the power supply wire out of the cable slot on the rear panel so that it produces about 430 mm form the front.
5. Insert the power supply wire fully into the terminal block and secure it tightly with screws.
Tighten torque: 1.2 N/m (0.12 kgf/m)
6. Clamp the power supply wire with the cord clamp.
7. Attach the terminal cover with a screw
CAUTION
• Be sure to refer to the wiring diagram attached inside the front panel.
• Check local electrical cords and also any specifi c wiring instructions and limitations.
• Do not catch the control wire when installing the clamp base.
<Stripping length of the
power supply wire>
<Connecting power supply wire>
R(L) S(N)
Cord clamp
Screw
Screw
Terminal cover
Terminal cover (UP)
Screw
Power supply
terminal block
Terminal block for control/wired
remote controller wiring
Cord clamp
Power supply
wire
Earth screw
430 mm
Earth wire for
power supply
wire
Power supply
terminal block
U1
A
B
U2
230
230
10
10
Shield wire
<Stripping length of the control wire>
Control wire
Remote control wire
Screw
Display base
Slot for fi x LED base
Hook for fi x LED base
Slide right side to
remove LED base
2) How to connect the control wiring
1. Take the control wire out of the cable slot on the rear panel so that it produces about 600 mm form the front.
2. Remove the terminal cover (UP)
3. Remove the LED BASE
4. Insert the control wire fully into the control/Wired remote controller terminal block
,
,
,
and secure it
tightly with screws.
5. Clamp the control wire with the cable clamp.
6. Pass the banding band through the hole of the mount base.
7. Band the control wire and the remote controller wire in the banding band.
8. Attach the LED base, terminal cover and front panel.
<Connecting control wire and remote controller>
<How to remove LED base>
Control wire
Remote controller wire
Terminal block for control/wired
remote controller wiring
Earth screw for
shield wire
Shield wire for
earth wire
Cable
clamp
LED base
600 mm