3
3
SELECTION OF INSTALLATION PLACE
SELECTION OF INSTALLATION PLACE
WARNING
• Install the air conditioner at enough strong place to withstand the weight of the unit.
If the strength is not enough, the unit may fall down resulting in injury.
CAUTION
• Do not install the air conditioner in a location subject to a risk of exposure to a combustible gas.
If a combustible gas leaks and stays around the unit, a fi re may occur.
Upon approval of the customer, install the air conditioner in a place that satisfi es the following
conditions.
• Place where the unit can be installed horizontally.
• Place where a suffi cient servicing space can be ensured for safety maintenance and check.
• Place where drained water will not cause any problem.
Avoid installing in the following places.
• Place exposed to air with high salt content (seaside area), or place exposed to large quantities of sulfi de gas (hot
spring).
(Should the unit be used in these places, special protective measures are needed.)
• A restaurant kitchen where a lot of oil is used or place near machines in a factory (Oil adhering to the heat
exchanger and resin part (cross fl ow fan) in the indoor unit may reduce the performance, generate mist or dew
drop, or deform or damage resin parts.)
• Place where organic solvent is used nearby.
• Place close to a machine generating high frequency.
• Place where the discharged air blows directly into the window of the neighbour house. (Outdoor unit)
• Place where noise of the outdoor unit is easily transmitted.
(When install the outdoor unit on the boundary with the neighbour, pay due attention to the level of noise.)
• Place with poor ventilation.
• Do not use the air conditioner for special purposes such as preserving food, precision instruments, or art objects, or
where breeding animals or growing plants are kept. (This may degrade the quality of preserved materials.)
• Place where any of high-frequency appliances (including inverter devices, private power generators, medical
equipment, and communication equipment) and inverter-type fl uorescent light is installed.
(A malfunction of the air conditioner, abnormal control, or problems due to noise to such appliances/equipment may
occur.)
• When the wireless remote controller is used in a room equipped with an inverter-type fl uorescent light or at a place
exposed to direct sunlight, signals from the remote controller may not be received correctly.
• Place where organic solvent is used.
• Place near a door or window exposed to humid outside air (Dew dropping may form.).
• Place where special spray is used frequently.
<Others>
Name
Owner’s manual
Installation manual
Installation plate
300 mm or more
300 mm or more
Shield pipe
300 mm or more
Installation diagram of indoor and outdoor units
Batteries
Insulate the refrigerant pipes separately
with insulation, not together.
8 mm thick heat resisting
polyethylene foam
Mounting screw
Wireless remote control
Pan head wood screw
Remote control holder
Do not allow the drain hose to get slack.
Make sure to run the drain hose sloped
downward.
Cut the piping
hole sloped
slightly.
Cut dot-line area
In case of right or left piping
Heat insulator
Air fi lter
Installation place
•
A place which provides the spaces around the indoor unit as shown in the diagram.
•
A place where there are no obstacles near the air inlet and outlet.
•
A place which allows easy installation of the piping to the outdoor unit.
•
A place which allows the front panel to be opened.
CAUTION
• Direct sunlight to the indoor unit’s wireless receiver should be avoided.
• The microprocessor in the indoor unit should not be too close to RF noise sources.
(For details, see the owner’s manual.)
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Left
Bottom right Rear
left
Bottom left
Rear right
99