12. Forced Defrosting Setting
• This function is available only for the header remote controller.
• This function can active the forced defrosting mode for the outdoor unit.
(Operation)
• Press the
button.
• Set the operation to the heating mode.
• After a while, forced defrosting signals are transmitted to the outdoor unit, and the unit starts defrosting.
(Forced defrosting lasts for up to 10 minutes.)
• After the defrosting, the heating operation starts.
• To perform defrosting again, start with
1
above.
(Performing the forced defrosting once cancels the forced defrosting setting above described.)
1
Press the [
] button and the [
] button at same time for 4
seconds or longer on the top screen to display the “FIELD SETTING
MENU”.
2
Press the [
] / [
] button to select “Forced defrosting” on the
FIELD SETTING screen, then press the [
] button.
3
Press the [
] button to select ON, then press the [
] button.
4
Start the heating operation on the top screen.
Test mode
FIELD SETTING MENU(1/2)
Floor drying
Forced defrosting
Information input
Alarm history
SET
Forced defrosting
ON
OFF