7.CHECKING THE EQUIPMENT STATUS WITH TopAccess
Error Codes 103
7 CHECKING THE EQUIPMENT STATUS WITH TopAccess
Error codes on scan jobs
The error indications on scan jobs are done as follows:
y
On TopAccess log list, messages indicating the status are displayed.
y
On the touch panel of the equipment, error codes are displayed. See the listings below.
Error Code
Problem Description
Corrective Action
2C10, 2C12,
2C13,
2C20-2C22
Wrong Job status
A system error has occurred during the sending of an
Email. Try it again. If the error still persists, contact your
service representative.
2C11
Not enough memory
Complete any running jobs first before reperforming the
job in error. If the error still persists, turn the power OFF
and then back ON, and then try again.
2C14
Invalid parameter specified
If you are using a template, create it again. If the error
still persists, turn the power OFF and then back ON,
and then try again.
2C15
Mail size exceeded limit or maximum size
You are sending too many documents at a time. Send
them separately.
2C30-2C33
Disk access error
Complete any running jobs first before reperforming the
job in error. If the error still persists, turn the power OFF
and then back ON, and then try again.
2C40
Failed to convert image file format
This error occurs when conversion to a highly
compressed PDF format fails. Do the scanning again. If
the error still persists, Use the normal PDF
format.When this error occurs in conversion other than
to a highly compressed PDF format, turn the power
OFF and then back ON. Then try to scan again. If the
error still persists, contact your service representative.
2C43
Encryption error. Failure to create a file
If the error still persists after reattempting, turn the
power OFF and then back ON. Then make another
effort.
2C44
Creating a file was not allowed
Creating an unencrypted file was not allowed.
Configure the encryption settings and try again.To
create an unencrypted file, consult the administrator.
2C45
Failure in making meta data
Make sure that the template setting is correct, and do
the scanning again. If the error still persists, turn the
power OFF and then back ON, and then try again.
2C60
HDD full failure during processing
Reduce the number of pages of the problem job and try
again. Check whether the server or local disk has
sufficient space in its capacity.
2C61
Failure to read Address Book
Turn the power OFF and then back ON. Try the
problem job again. Reset the data in the Address Book
and reattempt it. If the error still persists, contact your
service representative.
2C63
Terminal IP address unset
Ask your administrator to set the IP address of the
equipment.
2C64
Terminal mail address unset
Ask your administrator to set the Email address of the
equipment.
2C65, 2C66,
2C69
Failure to connect to SMTP server
Make sure that the SMTP server is correctly working or
the SMTP server address has been set correctly.
2C6A
Failure to send Email message
Turn the power OFF and then back ON. Try scanning
again. If the error still persists, contact your service
representative.
2C6B
Invalid address specified in From: field
Ask your administrator to check the SMTP
Authentication method or if there is an unpermitted
character in the Terminal mail address. Set the correct
SMTP Authentication method or delete the unpermitted
character in the Terminal mail address.
Содержание E-Studio 5540c
Страница 1: ...MULTIFUNCTIONAL DIGITAL COLOR SYSTEMS Troubleshooting Guide ...
Страница 4: ......
Страница 8: ...6 CONTENTS ...
Страница 64: ......
Страница 68: ......
Страница 116: ...114 INDEX W Waste toner box replacing 55 ...
Страница 117: ...FC 5540C 6540C 6550C OME10004800 ...