DP4500/3500 UPDATING THE FIRMWARE
6 - 30
December 2000 © TOSHIBA TEC
6.3.1 System firmware
(1) ROM type
There are two types of ROM to be downloaded.
(a) ROM for application downloading
The area in the FROM on the SYS board is updated. This ROM is used for the normal update.
The data to be overwritten by this ROM are as follows.
• System software
* This area cannot be downloaded using PC.
• Applications
• UI data fixed area
• UI data common area
• Default language
(b) ROM for UI data downloading
The language data in the HDD are updated.
The data to be updated by this ROM are as follows.
• UI data: The 1st to 5th languages
When downloading is performed using the ROM for UI data downloading, only UI data in the HDD are
updated.
To make these updated data effective, it is necessary to copy the result of the update into the FROM
by selecting a desired language in the setting mode “Language displayed at power ON” (08-220).