DP4500/3500 TROUBLESHOOTING
5 - 40
December 2000 © TOSHIBA TEC
[EA6] Finisher early arrival jam
MJ-1011
Is there any paper remaining on the transport path in the finisher or main unit?
YES
Remove the paper.
NO
Is the connector J10 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and inlet sensor (S2D) open-circuited?
YES
Connect the connector securely. Replace the harness.
NO
Is the inlet sensor working properly? (Check the movement of the actuator.)
NO
1. Connect the connector of the inlet sensor securely.
2. Attach the actuator securely if its shaft is out of place.
3. Replace the inlet sensor.
YES
Replace the finisher controller PC board.
MJ-1012/1013 (Finisher section)
Is there any paper remaining on the transport path in the finisher or main unit?
YES
Remove the paper.
NO
Is the connector J17 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and inlet sensor (PI1) open-circuited?
YES
Connect the connector securely. Replace the harness.
NO
Is the inlet sensor working properly? (Check the movement of the actuator.)
NO
1. Connect the connector of the inlet sensor securely.
2. Attach the actuator securely if its shaft is out of place.
3. Replace the inlet sensor.
YES
Replace the finisher controller PC board.
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
Содержание DP3500
Страница 91: ...DP4500 3500 PREVENTIVE MAINTENANCE 3 12 December 2000 TOSHIBA TEC ...
Страница 95: ...DP4500 3500 SUPPLIES 4 4 December 2000 TOSHIBA TEC ...
Страница 213: ...DP4500 3500 TROUBLESHOOTING 5 118 December 2000 TOSHIBA TEC ...
Страница 253: ...DP4500 3500 UPDATING THE FIRMWARE 6 40 December 2000 TOSHIBA TEC ...
Страница 254: ...December 2000 TOSHIBA TEC 7 1 DP4500 3500 WIRE HARNESS CONNECTION DIAGRAMS 7 WIRE HARNESS CONNECTION DIAGRAMS ...
Страница 256: ...DP4500 3500 WIRE HARNESS CONNECTION DIAGRAMS 7 4 December 2000 TOSHIBA TEC ...