DP4500/3500 TROUBLESHOOTING
5 - 70
December 2000 © TOSHIBA TEC
[Procedure 2]
Does the tray reach the tray upper limit detecting switch (MS5)?
NO
Lower the position of the tray.
YES
Is the tray upper limit detecting switch (MS5) working normally?
NO
Replace the switch.
YES
Is the wiring between the finisher controller PC board and the tray upper limit detecting switch
correct?
YES
Correct the wiring.
NO
Replace the finisher controller PC board.
[Procedure 3]
Does the tray move up/down?
NO
Is the power supplied to the motor from the finisher controller PC board when the
tray is moving?
NO
Replace the finisher controller PC board.
YES
Is there any problem with the tray elevation mechanism?
YES
Replace the tray lift motor (M5).
NO
Fix the tray elevation mechanism.
YES
Are the tray lift motor clock sensor-1/-2 (PI9/PI19) working normally?
NO
Replace the sensors.
YES
Replace the finisher controller PC board.
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼