December 2000 © TOSHIBA TEC
5 - 35
DP4500/3500 TROUBLESHOOTING
[EA4] Finisher front door opened during printing
MJ-1011
Is there any paper remaining on the transport path in the finisher or main unit?
YES
Remove the paper.
NO
Is the finisher connected with the main unit?
NO
Connect the finisher with the main unit.
YES
Is the connector J11 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and joint sensor (S4D) open-circuited?
YES
Connect the connector securely. Replace the harness.
NO
Is the joint sensor working properly?
NO
1. Connect the connector of the joint sensor securely.
2. Replace the joint sensor.
YES
Replace the finisher controller PC board.
MJ-1012/1013 (Finisher section)
Is there any paper remaining on the transport path in the finisher or main unit?
YES
Remove the paper.
NO
Is the finisher connected with the main unit?
NO
Connect the finisher with the main unit.
YES
Is the connector J12 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and joint sensor (PI15) open-circuited?
YES
Connect the connector securely. Replace the harness.
NO
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
Содержание DP3500
Страница 91: ...DP4500 3500 PREVENTIVE MAINTENANCE 3 12 December 2000 TOSHIBA TEC ...
Страница 95: ...DP4500 3500 SUPPLIES 4 4 December 2000 TOSHIBA TEC ...
Страница 213: ...DP4500 3500 TROUBLESHOOTING 5 118 December 2000 TOSHIBA TEC ...
Страница 253: ...DP4500 3500 UPDATING THE FIRMWARE 6 40 December 2000 TOSHIBA TEC ...
Страница 254: ...December 2000 TOSHIBA TEC 7 1 DP4500 3500 WIRE HARNESS CONNECTION DIAGRAMS 7 WIRE HARNESS CONNECTION DIAGRAMS ...
Страница 256: ...DP4500 3500 WIRE HARNESS CONNECTION DIAGRAMS 7 4 December 2000 TOSHIBA TEC ...