DP4500/3500 TROUBLESHOOTING
Defective area
Step
Check Items
Prescription
High-voltage transformer
(transfer charger/
developer bias)
Transfer charger wire
Developer unit
Drive system of developer
unit
Developer material
Developer polarity
Position of doctor blade
Drum
CCD, SLG, SYS, LGC
boards and harnesses
1
Is the output from the high-voltage
transformer normal?
2
Is the transfer charger wire cut off?
3
Is the developer unit installed properly?
4
Do the developer sleeve and mixers ro-
tate?
5
Is the developer material smoothly trans-
ported?
6
Has the magnetic brush phase been shifted?
7
Is the doctor blade positioned properly?
8
Is the drum rotating?
9
Are the connectors securely connected?
Check if the harnesses connecting the
boards are open-circuited.
Adjust the output, or replace the transformer.
Replace the transfer charger wire.
Check and correct the engaging condition of the
developer unit gears.
Check and fix the drive system of the developer
unit.
Remove the foreign object from the developer
material.
Adjust the developer polairty.
Adjust it using the doctor-sleeve jig.
Check if the drum shaft is inserted.
Check the drive system of the drum.
Connect the connectors securely.
Replace the harness.
(7) Blank copy
Feeding direction
Содержание DP3500
Страница 91: ...DP4500 3500 PREVENTIVE MAINTENANCE 3 12 December 2000 TOSHIBA TEC ...
Страница 95: ...DP4500 3500 SUPPLIES 4 4 December 2000 TOSHIBA TEC ...
Страница 213: ...DP4500 3500 TROUBLESHOOTING 5 118 December 2000 TOSHIBA TEC ...
Страница 253: ...DP4500 3500 UPDATING THE FIRMWARE 6 40 December 2000 TOSHIBA TEC ...
Страница 254: ...December 2000 TOSHIBA TEC 7 1 DP4500 3500 WIRE HARNESS CONNECTION DIAGRAMS 7 WIRE HARNESS CONNECTION DIAGRAMS ...
Страница 256: ...DP4500 3500 WIRE HARNESS CONNECTION DIAGRAMS 7 4 December 2000 TOSHIBA TEC ...