DP4500/3500 TROUBLESHOOTING
5 - 110
December 2000 © TOSHIBA TEC
Defective area
Step
Check Items
Prescription
Main charger
Transfer charger
Laser optical unit
Discharge lamp
Developer unit
Scanner section
1
Is the main charger dirty?
2
Is the transfer charger dirty?
3
Is the transfer charger wire dirty?
4
Is there any foreign object or stain on the
slit glass?
5
Is the discharge lamp dirty?
6
Are any of the discharge lamps off?
7
Is the magnetic brush in proper contact
with the drum?
8
Is the developer sleeve pressure
mechanism working?
9
Is the developer material transported nor-
mally?
10 (1) Is the platen cover open?
(2) Are the original glass (especially
shading position), mirrors and lens
dirty?
Clean or replace the charger wire.
Clean it.
Clean it.
Remove the foreign object.
Clean it.
Replace it.
Adjust the doctor-sleeve gap.
Check the mechanism.
Remove foreign objects if there are any.
(1) Close the platen cover.
(2) Clean them.
(16) Uneven image density
Feeding direction